介绍
ASME VIII-1 总则中的 UG-46给出了关于容器检查孔的通用要求,同时在规范的其它条款、规范案例以及释义里面也有提到: ASME VIII-1 检查孔参考条款 UG-46:
UG-46(a) – Vessels with compressed air or with corrosion, or with erosion, or with mechanical abrasion need inspection openings. Exemptions: UG-46(b) – use of telltale holes instead of inspection openings UG-46(c,d&e) – opening requirements and exemptions based on the diameter of the vessel UG-46(f&g) – what qualifies as an inspection opening based on size of the vessel and the opening size UG-46(h,i&j) – design of the opening
VIII-1关于检查孔的其它条款:
UG-32(o) and UG-33(j) – use the rules of UG-36 through UG-46 when designing openings in heads UG-42(e) – threaded inspection openings size vs threaded nozzle size UG-45 – exemption to mininum nozzle thickness requirements for inspection openings UCI-36(a) and UCD-36(a) – UG-46 applies to inspection openings in cast vessels with thickness restrictions UCL-25(b) – telltale holes instead of inspection openings in clad vessels ULW-16(a) and ULW-18(a&c) – inspection openings in layered vessels App 9-4(b) – inspection openings in jackets M-2(b) – inspection openings shall be accessible
规范案例:
释义:VIII-81-56 and VIII-77-11 – it is the users job to determine if a service is corrosive (caution: VIII-1-04-15 and VIII-1-07-63 define under what conditions air is considered non-corrosive) VIII-1-04-15, VIII-1-07-63 and VIII-1-89-93 – exemption per UG-46(a) for air, dried to -50°F and not VIII-1-86-31 – inspection openings are not required for non-corrosive service VIII-1-83-264 – if openings are to be used for inspection, the plugs must be supplied by the manufacturer VIII-1-83-336 – any size vessel can be non-corrosive and flexibility in sizing of openings VIII-1-83-358 – what qualifies as an inspection opening (this interpretation is probably superseded by code changes made in 1987) VIII-77-101 – inspection openings for heat exchangers and telltale holes (very old, probably superseded by code changes to UG-46 directly related to heat exchangers and use of telltale holes) VIII-80-93 – configuration of threaded openings 14-2223 – inspection nozzle size limits for cold-stretched vessels 15-748 – understanding UG-46 opening size requirements VIII-1-01-122 – corrosive service requires inspection openings even if the corrosion allowance is zero VIII-1-92-136, VIII-79-12 and VIII-1-95-115 – substitution of inspection nozzle sizes, and non-corrosive service VIII-1-95-46 – if a corrosion allowance is specified, then the service is corrosive unless otherwise stated on the MDR 更多动态,请关注我们官方网站:www.tuxren.com,或者关注我们的微信平台:asmecn 本文系网络转载,如涉及作品版权问题,请与我们联系 ASME中国制造感谢您一直以来的支持, 谢谢!
欢迎关注ASME中国制造微信公众号: 长按二维码 
|